Techno Press
Techno Press

Structural Engineering and Mechanics
  Volume 9, Number 3, March 2000 , pages 227-240
DOI: https://doi.org/10.12989/sem.2000.9.3.227
 


Optimal damping ratio of TLCDs
Chen YH, Chao CC

 
Abstract
    The study of the optimal damping ratio of a tuned liquid-column damper (or TLCD) attached to a single-degree-of-freedom system is presented. The tuned liquid-column damper is composed of two vertical columns connected by a horizontal section in the bottom and partially filled with water. The ratio of the length of the horizontal section to the effective wetted length of a TLCD considered as another important parameter is also presented for investigation. A simple pendulum-like model test is conducted to simulate a long-period motion in order to prove the effectiveness of TLCD for vibrational control. Comparisons of the experimental and analytic results of the TLCD, TLD (tuned-liquid damper), and TMD (tuned-mass damper) are included for discussion.

 
Key Words
    TLCD, optimal damping ratio, design parameter, experiment and comparison
 
Address
Chen YH, Natl Taiwan Univ, Dept Civil Engn, Taipei 10764, Taiwan
Natl Taiwan Univ, Dept Civil Engn, Taipei 10764, Taiwan
Natl Taiwan Univ, Dept Naval Architecture & Ocean Engn, Taipei 10764, Taiwan
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2026 Techno Press
P.O. Box 33, Yuseong, Daejeon 305-600 Korea, Tel: +82-42-828-7996, Fax : +82-42-828-7997, Email: admin@techno-press.com