Techno Press
Techno Press

Structural Engineering and Mechanics
  Volume 24, Number 1, September10 2006 , pages 91-105
DOI: https://doi.org/10.12989/sem.2006.24.1.091
 


Post-earthquake capacity evaluation of R/C buildings based on pseudo-dynamic tests
Dae-eon Kang and Waon-ho Yi

 
Abstract
    In this paper, post-earthquake capacity evaluation method of reinforced concrete buildings was studied. Substructure pseudo-dynamic test and static loading test of first story column in a four-story R/C building was carried out in order to investigate the validity of the evaluation method proposed in the Damage Assessment Guideline (JBDPA 2001). In pseudo-dynamic test, different levels of damage were induced in the specimens by pre-loading, and input levels of seismic motion, at which the specimens reached to the ultimate stage, were examined. From the experimental result, no significant difference in damage levels such as residual crack width between the specimens under static and pseudo-dynamic loading was found. It is shown that the seismic capacity reduction factors h can provide a reasonable estimation of post-earthquake seismic capacity of R/C buildings suffered earthquakes.
 
Key Words
    post-earthquake capacity; R/C; pseudo-dynamic test; damage levels; seismic capacity reduction factor
 
Address
ESnS Structure Research Center, Dept. of Architectural Engineeing, Kwangwoon University, Seoul, Korea
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2026 Techno Press