Abstract
This paper presents a comparison of results obtained by a newly developed numerical model for predicting the behaviour of structures under fire with experimental study carried out on heated and simply supported steel beam elements. A newly developed numerical model consists of three submodels: 3D beam model designed for calculating the inner forces in the structure, 2D model designed for calculation of stress and strain distribution over the cross section, including the section stiffness, and 3D transient nonlinear heat transfer model that is capable of calculating the temperature distribution along the structure, and the distribution over the cross section as well. Predictions of the calculated temperatures and vertical deflections obtained by the numerical model are compared with the results of the inhouse experiment in which steel beam element under load was heated for 90 minutes.

Key Words
fire; numerical model; heat transfer; finite element; steel

Address
Neno Toriū, Alen Harapin and Ivica Boko: University of Split, Faculty of Civil Engineering, Architecture and Geodesy, Matice Hrvatske 15, 21000 Split, Croatia.

Abstract
This article describes a simple and cost effective fabrication procedure by using hand lay-up technique that is employed for the manufacturing of thin-walled axi-symmetric composite shell structures with carbon, glass and hybrid woven fabric composite materials. The hand lay-up technique is very commonly used in aerospace and marine industries for making the complicated shell structures. A generic fabrication procedure is presented in this paper aimed at manufacture of plain Carbon Fabric Reinforced Plastic (CFRP) and Glass Fabric Reinforced Plastic (GFRP) shells using hand lay-up process. This paper delivers a technical breakthrough in fabrication of composite shell structures without any joints and wrinkling. The manufacture of stiffened CFRP shells, laminated CFRP shells and hybrid (carbon / glass / epoxy) composite shells which are valued by the aerospace industry for their high strength-to-weight ratio under axial loading have also been addressed in this paper. A fabrication process document which describes the major processing steps of the composite shell manufacturing process has been presented in this paper. A study of microstructure of the glass fabric/epoxy composite, carbon fabric/epoxy composite and hybrid carbon/glass/fabric epoxy composites using Scanning Electron Microscope (SEM) has been also carried out in this paper.

Key Words
composite structure; CFRP; GFRP; thin-walled shell; hybrid; hand lay-up; SEM

Address
(1) A. Vasanthanathan and P. Nagaraj: Department of Mechanical Engineering, MEPCO SCHLENK Engineering College, Sivakasi, India;
(2) B. Muruganantham: COSMOPLAST, Mahia Industrial Estate, Madurai, India.

Abstract
Composite special moment frame is one of the systems that are utilized in areas with low to high seismicity to deal with earthquake forces. Composite moment frames are composed of reinforced concrete columns (RC) and steel beams (S); therefore, the connection region is a combination of steel and concrete materials. In current study, a three dimensional finite element model of composite connections is developed. These connections are used in special composite moment frame, between reinforced concrete columns and steel beams (RCS). Finite element model is discussed as a most reliable and low cost method versus experimental procedures. Based on a tested connection model by Cheng and Chen (2005), the finite element model has been developed under cyclic loading and is verified with experimental results. A good agreement between finite element model and experimental results was observed. The connection configuration contains Face Bearing Plates (FBPs), Steel Band Plates (SBPs) enveloping around the RC column just above and below the steel beam. Longitudinal column bars pass through the connection with square ties around them. The finite element model represented a stable response up to the first cycles equal to 4.0% drift, with moderately pinched hysteresis loops and then showed a significant buckling in upper flange of beam, as the in test model.

Key Words
composite structure; RCS connection; panel zone; cyclic loading; plastic work

Address
Mohammad Hossein Habashizadeh Asl, Mohammad Reza Chenaglou, Karim Abedi and Hassan Afshin: Department of Civil Engineering, Sahand University of Technology, Sahand Town, Tabriz, Iran.

Abstract
In the case of seismic-resistant composite dual moment resisting and eccentrically braced frames, the current design practice is to avoid the disposition of shear connectors in the expected plastic zones, and consequently to consider a symmetric moment or shear plastic hinges, which occur only in the steel beam or link. Even without connectors, the real behaviour of the hinge may be different from the symmetric assumption, since the reinforced concrete slab is connected to the steel element close to the hinge locations, and also due to contact friction between the concrete slab and the steel element. The paper presents the results and conclusions of experimental tests on composite portal eccentrically braced frames and beam-to-column moment-resisting joints, carried out within the CEMSIG Research Centre of the Politehnica University of Timisoara, in order to check the validity of the assumption stated above. Reference steel and composite specimens with and without connectors in the plastic zones have been tested under monotonic and cyclic seismic type loading.

Key Words
composite beams; plastic hinges; connectors; experimental tests

Address
Gelu Danku, Dan Dubina and Adrian Ciutina: Department of Steel Structures and Structural Mechanics, Faculty of Civil Engineering and Architecture \"The Politehnica\" University, Str. Ioan Curea No. 1, Timisoara, Romania.

Abstract
In the case of seismic-resistant composite dual moment resisting and eccentrically braced frames, the current design practice is to avoid the disposition of shear connectors in the expected plastic zones, and consequently to consider a symmetric moment or shear plastic hinges, which occur only in the steel beam or link. Even without connectors, the real behavior of the hinge may be different from the symmetric assumption since the reinforced concrete slab is connected to the steel element close to the hinge locations, and also due to contact friction between the concrete slab and the steel element. At a larger level, the structural response in the case of important seismic motions depends directly on the elasto-plastic behavior of elements and hinges. The numerical investigation presented in this study summarizes the results of elasto-plastic analyses of several steel frames, considering the interaction of the steel beam with the concrete slab. Several parameters, such as the inter-story drift, plastic rotation requirements and behavior factors q were monitored. In order to obtain accurate results, adequate models of plastic hinges are proposed for both the composite short link and composite reduced beam sections.

Key Words
composite beams; plastic hinges; inter-storey drift; numerical models

Address
Gelu Danku, Dan Dubina and Adrian Ciutina: Department of Steel Structures and Structural Mechanics, Faculty of Civil Engineering and Architecture The \"Politehnica\" University, Str. Ioan Curea No. 1, Timisoara, Romania.

Abstract
Shear failure and core concrete crushing at plastic hinge region are the two main failure modes of bridge piers, which can make repair impossible and cause the collapse of bridge. To avoid the two types of failure of pier, a composite pier was proposed, which was formed by embedding high strength concrete filled steel tubular (CFT) column in reinforced concrete (RC) pier. Through cyclic loading tests, the seismic performances of the composite pier were studied. The experimental results show that the CFT column embedded in composite pier can increase the flexural strength, displacement ductility and energy dissipation capacity, and decrease the residual displacement after undergoing large deformation. The analytical analysis is performed to simulate the hysteretic behavior of the composite pier subjected to cyclic loading, and the numerical results agree well with the experimental results. Using the analytical model and history method, seismic responses of a continuous girder bridge using composite piers is investigated, and the results show that the bridge using composite piers can resist much stronger earthquake than the bridge using RC piers.

Key Words
reinforced concrete; concrete filled steel tube; composite pier; seismic responses; cyclic loading tests; damage; ductility

Address
(1) Wenliang Qiu, Shengshan Pan and Zhe Zhang: School of civil engineering, Dalian University of Technology, Dalian, P.R. China;
(2) Meng Jiang: School of hydraulic engineering, Dalian University of Technology, Dalian, P.R. China.


Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2024 Techno-Press ALL RIGHTS RESERVED.
P.O. Box 33, Yuseong, Daejeon 34186 Korea, Email: admin@techno-press.com