Abstract
In the present paper a transient three-dimensional thermo-mechanical model for concrete is presented. For given boundary conditions, temperature distribution is calculated by employing a three-dimensional transient thermal finite element analysis. Thermal properties of concrete are assumed to be constant and independent of the stress-strain distribution. In the thermo-mechanical model for concrete the total strain tensor is decomposed into pure mechanical strain, free thermal strain and load induced thermal strain. The mechanical strain is calculated by using temperature dependent microplane model for concrete (O
Key Words
concrete; high temperature; 3D finite element analysis; microplane model; thermo-mechanical model; headed studs.
Address
Josko Ozbolt; Institute for Construction Materials Stuttgart, University of Stuttgart, 70550 Stuttgart, GermanyrnIvica Kozar; Faculty of Civil Engineering, University of Rijeka, 51000 Rijeka, CroatiarnRolf Eligehausen and Goran Periskic; Institute for Construction Materials Stuttgart, University of Stuttgart, 70550 Stuttgart, Germany
Abstract
To date, many studies have been conducted for the analysis and design of reinforced concrete members with disturbed regions. However, prestressed concrete deep beams have not been the subject of many investigations. This paper presents an evaluation of the behavior and strength of three pre-tensioned concrete deep beams failed by shear and bond slip of prestressing strands using a nonlinear strut-tie model approach. In this approach, effective prestressing forces represented by equivalent external loads are gradually introduced along strand\'s transfer length in the nearest strut-tie model joints, the friction at the interface of main diagonal shear cracks is modeled by the aggregate interlock struts along the direction of the cracks in strut-tie model, and an algorithm considering the effect of bond slip of prestressing strands in the strut-tie model analysis and design of pre-tensioned concrete members is implemented. Through the strut-tie model analysis of pre-tensioned concrete deep beams, the nonlinear strut-tie model approach proved to present effective solutions for predicting the essential aspects of the behavior and strength of pre-tensioned concrete deep beams. The nonlinear strut-tie model approach is capable of predicting the strength and failure modes of pre-tensioned concrete deep beams including the anchorage failure of prestressing strands and, accordingly, can be employed in the practical and precise design of pre-tensioned concrete deep beams.
Key Words
pre-tensioned concrete deep beam; nonlinear strut-tie model approach; behavior and strength; gradual introduction of prestressing force; aggregate interlock strut; bond slip of prestressing strand.
Address
Department of Civil Engineering, Kyungpook National University, Daegu 702-701, Korea
Abstract
The development and the main features of an expert system for modeling the requirements of durable concrete in chemical exposure, called the Durable Concrete Advisor for Chemical Exposure (DCACE), are described. The system was developed to help improve the quality of concrete exposed to chemical environment by minimizing mistakes and deficiencies in selecting concrete constituents. Using Kappa-PC expert system shell, an object-oriented model was developed where the rule-based reasoning operates on or across objects. The American Concrete Institute manual of concrete practice was chosen as the main source of knowledge. Other textual sources were also consulted for knowledge acquisition. The major objectives of the research were acquisition and formalization of the relevant knowledge and building an expert system for making durable concrete for chemical exposure regarding sulfate attack, acid attack, seawater attack and carbonation. Similar to most expert systems, this system has explanation facilities, can be incrementally expanded, and has an easy to understand knowledge base. The performance of the system is demonstrated by an example session. The system is user-friendly and can be used as an educational tool.
Address
Department of Civil and Structural Engineering, Faculty of Engineering, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan, Malaysia
Abstract
The moment-curvature relationship of reinforced concrete beams made of normal- and high-strength concrete experiencing complex load history is studied using a numerical method that employs the actual stress-strain curves of the constitutive materials and takes into account the stress-path dependence of the concrete and steel reinforcement. The load history considered includes loading, unloading and reloading. From the results obtained, it is found that the complete moment-curvature relationship, which is also path-dependent, is similar to the material stress-strain relationship with stress-path dependence. However, the unloading part of the moment-curvature relationship of the beam section is elastic but not perfectly linear, although the unloading of both concrete and steel is assumed to be linearly elastic. It is also observed that when unloading happens, the variation of neutral axis depth has different trends for under- and over-reinforced sections. Moreover, even when the section is fully unloaded, there are still residual curvature and stress in the section in some circumstances. Various issues related to the post-peak behavior of reinforced concrete beams are also discussed.
Key Words
high-strength concrete; moment-curvature relationship; normal-strength concrete; reinforced concrete beams; stress-path dependence; unloading and reloading.
Address
Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, P.R. China
Abstract
Chloride ingress is a common cause of deterioration of reinforced concrete located in coastal zone. Modeling the chloride ingress is an important basis for designing reinforced concrete structures and for assessing the reliability of an existing structure. The modeling is also needed for predicting the deterioration of a reinforced structure. The existing deterministic solution for prediction model of corrosion initiation cannot reflect uncertainties which input variables have. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. There are a lot of prediction model for predicting the time of reinforcement corrosion of structures exposed to chloride-induced corrosion environment. In this work, RILEM model formula and Crank
Key Words
corrosion initiation time; service life; fuzzy; reinforced concrete; Monte Carlo simulation; probabilistic.
Address
Jeongyun Do; Faculty of Architectural and Urban, Chonbuk National University, Chonju 561-756, South KorearnHun Song; Korea Institute of Construction Technology, Koyang 411-712, South KorearnSeungyoung So and Yangseob Soh; Faculty of Architectural and Urban, Chonbuk National University, Chonju 561-756, South Korea