Techno Press
You logged in as Techno Press

Smart Structures and Systems
  Volume 2, Number 4, October 2006 , pages 321-328
DOI: https://doi.org/10.12989/sss.2006.2.4.321
 


Testing of rubber bearings for the dynamic damper of seismic isolated buildings
Mikayel Melkumyan and Alexander Hakobyan

 
Abstract
    The paper describes the testing facilities and the methodology on testing of laminated rubber bearings envisaged for application in the system of Dynamic Damper (DD) of seismic isolated buildings, as well as the obtained results. For the first time in Armenia laminated rubber bearings were tested simultaneously under the action of horizontal shear force and vertical tension force. The test results have proven the possibility of using rubber bearings as elements subjected to tension due to action of the mass of DD. Also it was confirmed that the suggested structural concept of DD for reducing the displacements and shear forces of seismic isolation systems will have reliable behavior during the design level earthquakes.
 
Key Words
    seismic isolation; dynamic damper; testing; rubber bearing; shear; tension; modulus; stiffness; displacement.
 
Address
Engineering Research Center, The American University of Armenia, 40 Marshal Baghramian st., 375019, Yerevan, Armenia
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2024 Techno Press
P.O. Box 33, Yuseong, Daejeon 305-600 Korea, Tel: +82-42-828-7996, Fax : +82-42-828-7997, Email: admin@techno-press.com