Rehabilitation of heavily earthquake damaged masonry building using steel straps
Sinan Altin, Fikret Kuran, Ozgur Anil and M. Emin Kara

 
Abstract
    The purpose of this study is to develop a rehabilitation technique for heavily earthquake damaged masonry buildings. A full scale one storey masonry building with window and door openings
was manufactured and tested on the shock table by applying increased amplitude free vibration up to the point where heavy earthquake damage was observed. Damaged test building was rehabilitated with vertical and diagonal steel straps and then tested again. The effectiveness of improvements obtained by the rehabilitation technique was investigated. Steel straps improved the lateral strength and stiffness of
masonry walls and limited the lateral displacement of building. Stability of the masonry walls were also improved by the steel straps. Steel straps reduced the natural period of the earthquake damaged masonry
building and prevented the failure of the building at the same amplitude of free vibration.
 
Key Words
    masonry building; earthquake damage; rehabilitation; steel strap.
 
Address
Sinan Altin: Gazi University, Dept. of Civil Engineering, Maltepe, Ankara, Turkey
Fikret Kuran: Dept. of Civil Engineering,The Turkish Ministry of Public Works and Settlement, Ankara, Turkey
Ozgur Anil: Gazi University, Dept. of Civil Engineering, Maltepe, Ankara, Turkey
M. Emin Kara: Aksaray University, Department. of Civil Engineering, Aksaray, Turkey
 