Techno Press
You logged in as. Techno Press

Steel and Composite Structures
  Volume 40, Number 5, September10 2021 , pages 761-780
DOI: https://doi.org/10.12989/scs.2021.40.5.761
 


Axial capacity of back-to-back built-up cold-formed stainless steel unlipped channels-Numerical investigation and parametric study
Krishanu Roy, Hieng Ho Lau, Zhiyuan Fang, Abdeliazim Mustafa Mohamed Ahmed and James B.P. Lim

 
Abstract
    In cold-formed steel structures, such as trusses, wall frames and portal frames, the use of back-to-back built-up cold-formed stainless steel unlipped channels as compression members are becoming popular. The advantages of using stainless steel as structural members are corrosion resistance and durability, compared with carbon steel. Current guidance by the American Iron and Steel Institute (AISI) and the Australian and New Zealand (AS/NZS) standards for built-up carbon steel sections describes a modified slenderness approach, to consider the spacing of the intermediate fasteners. The AISI and AS/NZS do not include the design of stainless-steel built-up channels and very few experimental tests or finite element (FE) analyses have been reported in the literature for such back-to-back cold-formed stainless steel unlipped channel section columns. This paper presents a numerical investigation on the behavior of back-to-back built-up cold-formed stainless steel unlipped channel section columns. Three different grades of stainless steel i.e., duplex EN1.4462, ferritic EN1.4003 and austenitic EN1.4404, were considered. The effects of screw spacing on the axial strength of such built-up unlipped channels were investigated. As expected, most of the short and intermediate columns failed by either local-global or local-distortional buckling interactions, whereas the long columns failed by global buckling. All three grades of stainless-steel stub columns failed by local buckling. A comprehensive parametric study was then carried out covering a wide range of slenderness and different cross-sectional geometries to assess the performance of the current design guidelines of carbon steel built-up sections in accordance with the AISI and AS/NZS. In total, 647 FE models were analyzed. From the results of the parametric study, it was found that the AISI and AS/NZS are conservative by around 14 to 20% for all three grades of stainless steel built-up unlipped channel section columns failed through global buckling. However, the AISI and AS/NZS carbon steel design rules can be un-conservative by around 8 to 13%, when they are used to calculate the axial capacity of those stainless steel built-up unlipped channels which are failed in local buckling.
 
Key Words
    axial strength; back-to-back sections; built-up sections; cold-formed stainless steel; finite element analysis; screw spacing; unlipped channels
 
Address
Krishanu Roy,Zhiyuan Fang and James B.P. Lim: Department of Civil and Environmental Engineering, The University of Auckland, Auckland, New Zealand
Hieng Ho Lau: Faculty of Engineering, Computing and Science, Swinburne University of Technology, Sarawak Campus, Kuching, Sarawak, Malaysia
Abdeliazim Mustafa Mohamed Ahmed: Department of Civil Engineering, College of Engineering, Prince Sattam Bin Abdulaziz University, Saudi Arabia
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2025 Techno Press
P.O. Box 33, Yuseong, Daejeon 305-600 Korea, Tel: +82-42-828-7996, Fax : +82-42-828-7997, Email: admin@techno-press.com