Techno Press
You logged in as Techno Press

Steel and Composite Structures
  Volume 24, Number 4, July20 2017 , pages 481-497
DOI: https://doi.org/10.12989/scs.2017.24.4.481
 


The ultimate bearing capacity of rectangular tunnel lining assembled by composite segments: An experimental investigation
Xian Liu, Xinyu Hu, Linxing Guan and Wei Sun

 
Abstract
    In this paper, full-scale loading tests were performed on a rectangular segmental tunnel lining, which was assembled by steel composite segments, to investigate its load-bearing structural behavior and failure mechanism. The tests were also used to confirm the composite effect by adding concrete inside to satisfy the required performance under severe loading conditions. The design of the tested rectangular segmental lining and the loading scheme are also described to better understand the bearing capacity of this composite lining structure. It is found that the structural ultimate bearing capacity is governed by the bond capacity between steel plates and the tunnel segment. The failure of the strengthened lining is the consequence of local failure of the bond at waist joints. This led to a fast decrease of the overall stiffness and eventually a loss of the structural integrity.
 
Key Words
    rectangular tunnel lining; composite segment; full-scale test; failure mechanism; ultimate bearing capacity
 
Address
(1) Xian Liu:
College of Civil Engineering, Tongji University, 1239 Siping Road, Shanghai,
China;
(2) Xinyu Hu:College of Urban Construction and Safety Engineering, Shanghai Institute of
Technology, 100 Haiquan Road, Shanghai, China;
(3) Linxing Guan, Wei Sun:Shanghai Municipal Engineering Design Institute (Group) Co. Ltd., 901 North Zhongshan no.2 Road, Shanghai, China.
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2024 Techno Press
P.O. Box 33, Yuseong, Daejeon 305-600 Korea, Tel: +82-42-828-7996, Fax : +82-42-828-7997, Email: admin@techno-press.com