Techno Press
You logged in as. Techno Press

Computers and Concrete
  Volume 8, Number 5, October 2011 , pages 583-595
DOI: https://doi.org/10.12989/cac.2011.8.5.583
 


Efficiency factor of high calcium Class F fly ash in concrete
V. Sata, P. Khammathit and P. Chindaprasirt

 
Abstract
    This paper studied the cement efficiency factor (k factor) of high calcium Class F fly ash. This k factor represents a unit of fly ash with efficiency equivalent to k unit of cement. The high calcium Class F fly ash was used to replace cement in concrete. The modified Bolomey
 
Key Words
    efficiency factor; fly ash; Class F; concrete; multi-linear regression analysis.
 
Address
V. Sata, P. Khammathit and P. Chindaprasirt: Sustainable Infrastructure Research and Development Center,
Department of Civil Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002, Thailand
 

Techno-Press: Publishers of international journals and conference proceedings.       Copyright © 2025 Techno Press
P.O. Box 33, Yuseong, Daejeon 305-600 Korea, Tel: +82-42-828-7996, Fax : +82-42-828-7997, Email: admin@techno-press.com