CONTENTS | |
Volume 26, Number 6, June 2024 |
|
- The effect of infill walls on the fundamental period of steel frames by considering soil-structure interaction Kianoosh Kiani and Sayed Mohammad Motovali Emami
| ||
Abstract; Full Text (2838K) . | pages 417-431. | DOI: 10.12989/eas.2024.26.6.417 |
Abstract
The fundamental period of vibration is one of the most critical parameters in the analysis and design of structures, as it depends on the distribution of stiffness and mass within the structure. Therefore, building codes propose empirical equations based on the observed periods of actual buildings during seismic events and ambient vibration tests. However, despite the fact that infill walls increase the stiffness and mass of the structure, causing significant changes in the fundamental period, most of these equations do not account for the presence of infills walls in the structure. Typically, these equations are dependent on both the structural system type and building height. The different values between the empirical and analytical periods are due to the elimination of non-structural effects in the analytical methods. Therefore, the presence of non-structural elements, such as infill panels, should be carefully considered. Another critical factor influencing the fundamental period is the effect of Soil-Structure Interaction (SSI). Most seismic building design codes generally consider SSI to be beneficial to the structural system under seismic loading, as it increases the fundamental period and leads to higher damping of the system. Recent case studies and postseismic observations suggest that SSI can have detrimental effects, and neglecting its impact could lead to unsafe design, especially for structures located on soft soil. The current research focuses on investigating the effect of infill panels on the fundamental period of moment-resisting and eccentrically braced steel frames while considering the influence of soil-structure interaction. To achieve this, the effects of building height, infill wall stiffness, infill openings and soil structure interactions were studied using 3, 6, 9, 12, 15 and 18-story 3-D frames. These frames were modeled and analyzed using SeismoStruct software. The calculated values of the fundamental period were then compared with those obtained from the proposed equation in the seismic code. The results indicate that changing the number of stories and the soil type significantly affects the fundamental period of structures. Moreover, as the percentage of infill openings increases, the fundamental period of the structure increases almost linearly. Additionally, soil-structure interaction strongly affects the fundamental periods of structures, especially for more flexible soils. This effect is more pronounced when the infill wall stiffness is higher. In conclusion, new equations are proposed for predicting the fundamental periods of Moment Resisting Frame (MRF) and Eccentrically Braced Frame (EBF) buildings. These equations are functions of various parameters, including building height, modulus of elasticity, infill wall thickness, infill wall percentage, and soil types.
Key Words
EBF; fundamental period; infill wall; soil-structure interaction; steel moment resisting
Address
Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran
- Comparison of methods to estimate storey stiffness and storey strength in buildings A.R.Vijayanarayanan, M.Saravanan and M. Surendran
| ||
Abstract; Full Text (2309K) . | pages 433-447. | DOI: 10.12989/eas.2024.26.6.433 |
Abstract
During earthquakes, regular buildings perform better than irregular buildings. In general, seismic design codes define a regular building using estimates of Storey Stiffness and Storey Strength. At present, seismic design codes do not recommend a specific method to estimate these parameters. Consequently, any method described in the literature can be applied to estimate the aforementioned parameters. Nevertheless, research has demonstrated that storey stiffness and storey strength vary depending on the estimation method employed. As a result, the same building can be regular or irregular, depending on the method employed to estimate storey stiffness and storey strength. Hence, there is a need to identify the best method to estimate storey stiffness and storey strength. For this purpose, the study presents a qualitative and quantitative evaluation of nine approaches used to determine storey stiffness. Similarly, the study compares six approaches for estimating storey strength. Subsequently, the study identifies the best method to estimate storey stiffness and storey strength using results of 350 linear time history analyses and 245 nonlinear time history analyses, respectively. Based on the comparison, it is concluded that the Fundamental Lateral Translational Mode Shape Method and Isolated Storey Method - A Particular Case are the best methods to estimate storey stiffness and storey strength of low-to-mid rise buildings, respectively.
Key Words
lateral strength; irregularity; lateral translational stiffness; soft storey; weak storey
Address
A.R.Vijayanarayanan: Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, India
M.Saravanan and M. Surendran: Structural Engineering Research Center, CSIR, Chennai, India
- Effect of vertical reinforcement connection level on seismic behavior of precast RC shear walls: Experimental study Yun-Lin Liu, Sushil Kumar, Dong-Hua Wang and Dong Guo
| ||
Abstract; Full Text (1945K) . | pages 449-461. | DOI: 10.12989/eas.2024.26.6.449 |
Abstract
The vertical reinforcement connection between the precast reinforced concrete shear wall and the cast-in-place reinforced concrete member is vital to the performance of shear walls under seismic loading. This paper investigated the structural behavior of three precast reinforced concrete shear walls, with different levels of connection (i.e., full connection, partial connection, and no connection), subjected to quasi-static lateral loading. The specimens were subjected to a constant vertical load, resulting in an axial load ratio of 0.4. The crack pattern, failure modes, load-displacement relationships, ductility, and energy dissipation characteristics are presented and discussed. The resultant seismic performances of the three tested specimens were compared in terms of skeleton curve, load-bearing capacity, stiffness, ductility, energy dissipation capacity, and viscous damping. The seismic performance of the partially connected shear wall was found to be comparable to that of the fully connected shear wall, exhibiting 1.7% and 3.5% higher yield and peak load capacities, 9.2% higher deformability, and similar variation in stiffness, energy dissipation capacity and viscous damping at increasing load levels. In comparison, the seismic performance of the non-connected shear wall was inferior, exhibiting 12.8% and 16.4% lower loads at the yield and peak load stages, 3.6% lower deformability, and significantly lower energy dissipation capacity at lower displacement and lower viscous damping.
Key Words
grout sleeve connection; precast shear wall; quasi-static loading; seismic behavior; vertical reinforcement connection
Address
Yun-Lin Liu: 1)Prefabricated Building Research Institute of Anhui Province, Anhui Jianzhu University, Hefei, China, 2) School of Civil Engineering, Anhui Jianzhu University, Hefei, China, 3)Department of Modern Mechanics, University of Science and Technology of China
Sushil Kumar: Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University, Hong Kong, China
Dong-Hua Wang: 1)Prefabricated Building Research Institute of Anhui Province, Anhui Jianzhu University, Hefei, China, 2) School of Civil Engineering, Anhui Jianzhu University, Hefei, China
Dong Guo: School of Civil Engineering, Guangzhou University, Guangzhou, China
Abstract
The study aims to investigate the pounding that occurs between the isolator's ring and slider of isolated structures resulting from excessive seismic excitation, while considering soil-structure interaction. The dynamic responses and poundings of structures subjected a series seismic records were comparatively analyzed for three different soil types and fixed-base structures. A series of parametric studies were conducted to thoroughly discuss the effects of the impact displacement ratio, the FPB friction coefficient ratio, and the radius ratio on the structural dynamic response when considering impact and SSI. It was found that the pounding is extremely brief, with an exceptionally large pounding force generated by impact, resulting in significant acceleration pulse. The acceleration and inter-story shear force of the structure experiencing pounding were greater than those without considering pounding. Sudden changes in the inter-story shear force between the first and second floors of the structure were also observed. The dynamic response of structures in soft ground was significantly lower than that of structures in other ground conditions under the same conditions, regardless of the earthquake wave exciting the structure. When the structure is influenced by pulse-type earthquake records, its dynamic response exhibits a trend of first intensifying and then weakening as the equivalent radius ratio and friction coefficient ratio increase. However, it increases with an increase in the pounding displacement ratio, equivalent radius ratio, friction coefficient ratio, and displacement ratio when the structures are subjected to non-pulse-type seismic record.
Key Words
friction pendulum bearing (FPB); pounding; seismic response; soil-structure interaction (SSI)
Address
Yingna Li: 1) School of Transportation and Civil Engineering, Nantong University, Nantong, 226019, China, 2) Zhixing Technology Nantong Co., Ltd, Nantong, 226010, China
Jingcai Zhang: 1) School of Transportation and Civil Engineering, Nantong University, Nantong, 226019, China, 2) Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, Harbin Institute of Technology, Harbin, 150090, China, 3) Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology, Harbin, 150090, China
- Numerical investigations of structure-soil-structure interaction on footing forces due to adjacent building Shrish Chandrawanshi and Vivek Garg
| ||
Abstract; Full Text (2112K) . | pages 477-487. | DOI: 10.12989/eas.2024.26.6.477 |
Abstract
The interaction between multiple structures through the supporting soil media, known as structure-soil-structure interaction (SSSI), has become an increasingly important issue due to rapid urbanization. There is a need to investigate the effect of SSSI on the structural response of buildings compared to non-interaction analysis (NIA) and soil-structure interaction (SSI) analysis. In the present study, two identical 4-bay*4-bay, three-story RCC buildings are modeled adjacent to each other with a soil domain beneath it to investigate the effect of SSSI on the forces experienced by footings under gravity and seismic load cases. The ANSYS software is used for modeling various non-interaction and interaction models which work on the principle of FEM. The results indicate that in most of the footings, the SSSI effect causes a significant redistribution of forces compared to SSI and NIA under both gravity and seismic load cases. The maximum interaction effect is observed on the footings that are closer to the adjacent building. The axial force, shear force and bending moment values on these footings show that SSI causes a significant increase in these values compared to non-interaction analysis but the presence of adjacent building relieves these forces significantly.
Key Words
adjacent building; ANSYS; FEM; footing force; seismic loading; structure-soil-structure interaction
Address
Department of Civil Engineering, Maulana Azad National Institute of Technology, Bhopal, India
- Out-of-plane performance of infill masonry walls reinforced with post-compressed wedges under lateral-concentrated push load Sanghee Kim, Ju-Hyun Mun, Jun-Ryeol Park, Keun-Hyeok Yang and Jae-Il Sim
| ||
Abstract; Full Text (2069K) . | pages 489-499. | DOI: 10.12989/eas.2024.26.6.489 |
Abstract
Infill masonry walls are vulnerable to lateral loads, including seismic, wind, and concentrated push loads. Various strengthening metal fittings have been proposed to improve lateral load resistance, particularly against seismic loads. This study introduces the use of post-compressed wedges as a novel reinforcement method for infill masonry walls to enhance lateral load resistance. The resistance of the infill masonry wall against lateral-concentrated push loads was assessed using an out-of-plane push-over test on specimens sized 2,300*2,410*190 mm3. The presence or absence of wedges and wedge spacing were set as variables. The push-over test results showed that both the unreinforced specimen and the specimen reinforced with 300 mm spaced wedges toppled, while the specimen reinforced with 100 mm spaced wedges remained upright. Peak loads were measured to be 0.74, 29.77, and 5.88 kN for unreinforced specimens and specimens reinforced with 100 mm and 300 mm spaced wedges, respectively. Notably, a tighter reinforcement spacing yielded a similar strength, as expected, which was attributed to the increased friction force between the masonry wall and steel frame. The W-series specimens exhibited a trend comparable to that of the displacement ductility ratio. Overall, the findings validate that post-compressed wedges improve the out-of-plane strength of infill masonry walls.
Key Words
infill masonry wall; lateral-concentrated push load; post-compressed method; push-over test; wedge
Address
Sanghee Kim, Ju-Hyun Mun, Jun-Ryeol Park and Keun-Hyeok Yang: Department of Architectural Engineering, Kyonggi University, Suwon, Republic of Korea
Jae-Il Sim: Korea Disaster Prevention Safety Technology Co. Ltd, Gwangju, Republic of Korea